CEN0004-AC/DC Clamp Meter (True RMS,Watt)
|
232 is used in power system maintenance. Beside power measurement, it also provides the voltage, current measurement and continuality function. Features:
4 Digital Display.
TRUE RMS.
Autoranging.
Auto Power Off.
Peak Hold Function.
Data Hold Function.
Auto Zero.
|
Clamp meters
|
|
|
PRO0021-6200 Datalogging Power Clamp
|
Analysis for Single Phase and Balanced 3 phase system
True RMS Value (V and I)
Active Power (K,KW,MW,GW)
Apparent (VA,KVA,MVA) and Reactive Power (VAR,KVAR,MVAR)
Power Factor (PF), Phase Angle( Φ )
Energy (WH,KWH,KVARH,PFH)
Programmable PT(1 to 3000)Ratios
Display of Overlapped Voltage and Current Waveform
Maximum Demand (MD in W,KW,MW) with programmable Period
Harmonic Analysis (V and I) to 50th Order
Display of 25 Harmonics in one screen
Optical Isolated RS-232C Interface
Smart Datalogging to save Battery
|
Clamp meters
|
|
|
TEN010-TM-1017V3 400A TRUE-RMS AC POWER CLAMP METER + PHASE ROTATION
|
CAT III 600V Maximum conductor size 30mm. Display counts: 4000. Measures: ACV, DCV, ACA. Measures Phase Sequence. Voltage/Current Harmonics to 25th with THD. W3ø, HV, HA, Phase SEQ, Audible continuity tests. Frequency to 400Hz. Active, Reactive, Apparent power/ energy on. Power Factor, cosø on Single/Three phase systems. Phase sequence. |
Clamp meters
|
|
|
PRO0021-6200V3 Graphic Power Clamp for 1-,3-phase (PF,Harmoncs,KWH)
|
Analysis for Single Phase and Balanced 3 phase system
True RMS Value (V and I)
Active Power (K,KW,MW,GW)
Apparent (VA,KVA,MVA) and Reactive Power (VAR,KVAR,MVAR)
Power Factor (PF), Phase Angle( Φ )
Energy (WH,KWH,KVARH,PFH)
Programmable PT(1 to 3000)Ratios
Display of Overlapped Voltage and Current Waveform
Maximum Demand (MD in W,KW,MW) with programmable Period
Harmonic Analysis (V and I) to 50th Order
Display of 25 Harmonics in one screen
Optical Isolated RS-232C Interface
Smart Datalogging to save Battery
Datalogging of 32,64,128 or 256 points/cycles
Analysis of Total Harmonic Distortion (%THD-F)
Graphic Phasor Diagram
Capture 128 Transient Events (Time+Cycles+Faults) with Programmable Threshold(%),also can be reviewed in LCD
50000 Records with Programmable Interval (1 to 6000 seconds)
Real-time Output of Waveform, Power Parameters and Harmonics at Command
Large Dot Matrix LCD Display with Backlight
Power for Long-term Monitoring
Built -in Calendar Clock for Data Logging
General Specification:
Conductor Size
55mm(approx.), 64*24mm(bus bar)
Battery Type
Two... |
Power clamps
|
|
|
LUT0366-Clamp power analyser 2000amps 600VAC SD logging (Same as Fluke 345)
|
The clamp power analyser is a very economical solution for the analysis of single phase or balanced 3 phase systems with voltages to 600VAC and current to 2000 amps. The product uses the same SD card logging. Readings are logged from every 2 second to 7200 seconds as instantaneous values. It also captures 3 types of transient events with programmable threshold. The display is graphical dot matrix and has many graphic formats including waveform on voltage and current - phasor diagram and others.
Measures ACV, ACA, KW, KVA, KVAR, PF
Measures KWH, KVAH, KVARH, PFH
Frequency, harmonics to 50th
Type K thermocouple input 0.1 resolution to 199.9C then 1C to 1200C
SD card logging
Cables to 57mm 10amps to 2000amps autorange
Record graphic displays to memory as .bmp files
|
Power clamps
|
|