|
Fluke 705 Loop Calibrator
|
A large display and simple, pushbutton interface for ease of use.
Simultaneous mA and % readout for quick, easy interpretation of readings.
mA accuracy of 0.02%
Push button 25% steps for fast, easy linearity checks. Save time over traditional knob type controls.
"Span Check" for fast confirmation of zero and span.
Selectable slow ramp, fast ramp, and step to provide smooth outputs for valve slewing and loop functional tests.
24 volt internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM.
Single 9V battery that is easily changed.
0 - 20 mA or 4 - 20 mA default start up modes.
|
Calibrators
|
|
|
Fluke 707 Loop Calibrator
|
Large display and simple, quick-click interface for easy one-handed operation
Simultaneous mA and % readout for quick, easy, interpretation of readings
mA accuracy of 0.015%, superior to other loop calibrators in this price range
1µA resolution for mA source, simulate and measure
Push button 25% steps for fast, easy linearity checks
0-100% "span check" for fast confirmation of zeroand span
Measures V dc to 28 V
Selectable slow ramp, fast ramp, and step ramp to provide smooth outputs for valve slewing and loop functional tests
24 volt internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM
Single 9 V battery that is easily changed
0-20 mA or 4-20 mA default start up modes
Innovative output adjustment dial with 1 µAand 100 µA resolution
HART™ mode connects 250 W resistor in serieswith 24 V loop for compatibility with HART communicators.
Also available Fluke 707EX Intrinsically safe model
|
Calibrators
|
|
|
Fluke 707EX Intrinsically Safe Loop Calibrator
|
ATEX Intrinsic Safe Certification for use in classified areas.
Large display and simple, quick-click push rotary button for easy one-handed operation
Simultaneous mA and % readout for quick, easy, interpretation of readings
mA accuracy of 0.015 %, superior to other loop calibrators
1 µA resolution for mA source, simulate and measure
Push button with 25 % steps for fast, easy linearity checks
0-100 % "span check" for fast confirmation of zero and span
Selectable slow ramp, fast ramp, and step ramp to provide smooth outputs for valve slewing and loop functional tests
Internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM
Measures V dc to 28 V
Single 9 V battery that is easily changed
Innovative output adjustment dial with 1µA and 100 µA resolution
HART® compatible resistance is connected in series with the loop supply for compatibility with HART communicators
|
Calibrators
|
|
|
Fluke 712 RTD Process Calibrator
|
Measure temperature from RTD output
Simulate RTD output
Operates with seven types of RTDs
Measure additional RTDs using Ohms measurement function
Simulate additional RTDs using Ohms source function
°F or °C selectable
Four shrouded banana jacks
Compatible with Rosemount® pulsed RTD transmitters(pulses > 100ms)
|
Calibrators
|
|
|
Fluke 714 Thermocouple Calibrator
|
Measure temperature from Thermocouple output
Simulate Thermocouple output
Operable with nine types of thermocouples
Calibrate linear Thermocouple transmitter with mV source function
Selectable °F or °C
Thermocouple mini-jack termination
|
Calibrators
|
|
|
Fluke 715 Volt/mA Loop Calibrator
|
Measure loop current (0-20 mA, 4-20 mA) signals with very high accuracy of 0.015% and 1 mA resolution
Measure voltage output process signals from PLCs, transmitters
Source or simulate 24 mA loop current
Source voltage to 100 mV or 10V
24V loop supply with simultaneous current measurement
Enhanced voltage and current measure and source accuracy
Improved battery life
250 ohm HART resistor with loop power
Holster features test lead storage
Compatible with toolpack magnetic hanging system
Step and linear ramp output function
Configurable zero and span settings
|
Calibrators
|
|
|
Fluke 717 and Fluke 718 Pressure Calibrators
|
General Features:
Measure pressure and vacuum to 0.05% of full scale with internal 30 or 100 psig sensor
1/8 NPT pressure fitting
Compatible with non-corrosive gasses and liquids
Measure pressure to 10,000 psi/69 mPa using one of 29 Fluke 700Pxx Pressure Modules
Measure mA with 0.025% accuracy and 0.001 mA resolution, while providing 24 volt loop power
New built-in pressure switch test feature
Min/Max/Hold functions
Fluke 718 Features:
Built-in pressure/vacuum hand pump, with vernier and bleed valve
Pressure and vacuum measurement to 0.05% of full span, using an internal pressure sensor (dry air only)
|
Calibrators
|
|
|
Fluke 718EX-30, 718EX-100 and 718EX-300 Intrinsically Safe Pressure Calibrators
|
ATEX II 1G EEx ia IIC T4 Compliant
Built-in pressure / vacuum hand pump, with fine adjust vernier and bleed valve
Pressure measurement to 0.05% of full span, using an internal pressure sensor
Pressure measurement to 200 bar using any of eight intrinsically safe Fluke 700PEx Pressure Modules
Wide range of selectable measurement units for pressure
Current measurement with 0.02% accuracy and 0.001 mA resolution
Pressure switch test function
Min-Max Hold functions
Simple, push-button user interface
Rugged and reliable, ideal for field use
|
Calibrators
|
|