|
|
Megger 220005 and 220015 5 and 15 kV DC Dielectric Test Set
|
Continuously variable test voltage
Rugged field construction
Compact and portable
|
Megger
|
|
|
|
Megger 220005 and 220015 5 and 15 kV DC Dielectric Test Set
|
Continuously variable test voltage
Rugged field construction
Compact and portable
|
Megger
|
|
|
|
Megger 21805-3CL 500 V Midget Insulation Tester
|
Test Voltage of 500 VDC
Insulation Resistance 0-200 Megohms
Easy-to-Read Analog Scale - No Multipliers
Automatic Discharge of Item Under Test
|
Megger
|
|
|
|
Megger 212559 MJ559 Major Megger Line/Battery Powered Insulation Resistance Tester 100, 250, 500 & 1000 V; 2 GOhms
|
No scale multipliers
Multiple test voltages for spot and step voltage testing
Guard terminal to eliminate surface leakage current
Dual operation 120 V 50/60 Hz mains (line) supply and rechargeable battery. Six NiMh 1800 mAh cells
Available in alternate configurations:
212159 - Low voltage brushless a.c. generator. Cranking speed between 130 rpm and 170 rpm
212359 - Dual operation low voltage brushless a.c. generator or 120 V 50/60 Hz mains (line) supply
212459 - Six IEC LR6 cells (AA) Battery life: not less than 1300 insulation or Resistance range tests
|
Megger
|
|
|
|
Megger 212459 MJ459 Major Megger Battery Powered Insulation Resistance Tester 100, 250, 500 & 1000 V; 2 GOhms
|
No scale multipliers
Multiple test voltages for spot and step voltage testing
Guard terminal to eliminate surface leakage current
Six IEC LR6 cells (AA) Battery life: not less than 1300 insulation or Resistance range tests
Available in alternate configurations:
212159 - Low voltage brushless a.c. generator. Cranking speed between 130 rpm and 170 rpm
212359 - Dual operation low voltage brushless a.c. generator or 120 V 50/60 Hz mains (line) supply
212559 - Dual operation 120 V 50/60 Hz mains (line) supply and rechargeable battery. Six NiMh 1800 mAh cells
|
Megger
|
|
|
|
Megger 212359 MJ359 Major Megger Line/Hand-Cranked Insulation Resistance Tester 100, 250, 500 & 1000 V; 2 GOhms
|
No scale multipliers
Multiple test voltages for spot and step voltage testing
Guard terminal to eliminate surface leakage current
Dual operation low voltage brushless a.c. generator or 120 V 50/60 Hz mains (line) supply
Available in alternate configurations:
212159 - Low voltage brushless a.c. generator. Cranking speed between 130 rpm and 170 rpm
212459 - Six IEC LR6 cells (AA) Battery life: not less than 1300 insulation or Resistance range tests
212559 - Dual operation 120 V 50/60 Hz mains (line) supply and rechargeable battery. Six NiMh 1800 mAh cells
|
Megger
|
|
|
|
Megger 212159 MJ159 Major Megger Hand-Cranked Insulation Resistance Tester 100, 250, 500 & 1000 V; 2 GOhms
|
No scale multipliers
Multiple test voltages for spot and step voltage testing
Guard terminal to eliminate surface leakage current
Low voltage brushless a.c. generator. Cranking speed between 130 rpm and 170 rpm
Available in alternate configurations:
212359 - Dual operation low voltage brushless a.c. generator or 120 V 50/60 Hz mains (line) supply
212459 - Six IEC LR6 cells (AA) Battery life: not less than 1300 insulation or Resistance range tests
212559 - Dual operation 120 V 50/60 Hz mains (line) supply and rechargeable battery. Six NiMh 1800 mAh cells
|
Megger
|
|
|
|
Megger 210600 Digital Major Megger Insulation Tester (Battery operated)
|
Test Voltages of 100/250/500/1000 VDC
Insulation resistance measurements up to 1999 MΩ
0 to 600 VAC Measuring Range
Guard terminal to eliminate surface leakage current
Battery Operated
Autoranging
Large easy-to-read 3Ω LCD display
|
Megger
|
|