BANTE 931-Cu Precision Cupric Ion Meter
|
Features:
2 to 5 points push-button calibration from low to high concentrations.
Selectable multiple concentration units, including ppm, mg/L and mol/L.
Direct readout ion concentration simplifies the elaborate measurement
process.
mV measurement allows user to check performance of ion electrode.
AutomaticTemperature Compensation (ATC) ensures highly accurate
measurements over the entire range.
Automatic endpoint function freezes the stable measured values for
easy reading and recording data.
Calibration due reminder prompts you to calibrate the meter regularly.
Help message as aoperational guide to helps you understand how to
use meter.
Setup menu lets user customize calibration points, ion concentration
units, stability conditions, temperature units, date and time to meet
measurement requirements.
Reset function can resumes all settings to factory default values.
Expanded memory stores and recalls up to 500 readings.
Built-in real-time clock stamps stored data to meets GLP standards.
Stored data can be transferred into computer... |
Ion Meters
|
|
|
|
BANTE 931-I Precision Iodide Ion Meter
|
Features:
2 to 5 points push-button calibration from low to high concentrations.
Selectable multiple concentration units, including ppm, mg/L and mol/L.
Direct readout ion concentration simplifies the elaborate measurement
process.
mV measurement allows user to check performance of ion electrode.
AutomaticTemperature Compensation (ATC) ensures highly accurate
measurements over the entire range.
Automatic endpoint function freezes the stable measured values for
easy reading and recording data.
Calibration due reminder prompts you to calibrate the meter regularly.
Help message as aoperational guide to helps you understand how to
use meter.
Setup menu lets user customize calibration points, ion concentration
units, stability conditions, temperature units, date and time to meet
measurement requirements.
Reset function can resumes all settings to factory default values.
Expanded memory stores and recalls up to 500 readings.
Built-in real-time clock stamps stored data to meets GLP standards.
Stored data can be transferred into computer... |
Ion Meters
|
|
|
|
BANTE 931-Pb Precision Lead Ion Meter
|
Features:
2 to 5 points push-button calibration from low to high concentrations.
Selectable multiple concentration units, including ppm, mg/L and mol/L.
Direct readout ion concentration simplifies the elaborate measurement
process.
mV measurement allows user to check performance of ion electrode.
AutomaticTemperature Compensation (ATC) ensures highly accurate
measurements over the entire range.
Automatic endpoint function freezes the stable measured values for
easy reading and recording data.
Calibration due reminder prompts you to calibrate the meter regularly.
Help message as aoperational guide to helps you understand how to
use meter.
Setup menu lets user customize calibration points, ion concentration
units, stability conditions, temperature units, date and time to meet
measurement requirements.
Reset function can resumes all settings to factory default values.
Expanded memory stores and recalls up to 500 readings.
Built-in real-time clock stamps stored data to meets GLP standards.
Stored data can be transferred into computer... |
Ion Meters
|
|
|
|
BANTE 931-Ag Precision Silver Ion Meter
|
Features:
2 to 5 points push-button calibration from low to high concentrations.
Selectable multiple concentration units, including ppm, mg/L and mol/L.
Direct readout ion concentration simplifies the elaborate measurement
process.
mV measurement allows user to check performance of ion electrode.
AutomaticTemperature Compensation (ATC) ensures highly accurate
measurements over the entire range.
Automatic endpoint function freezes the stable measured values for
easy reading and recording data.
Calibration due reminder prompts you to calibrate the meter regularly.
Help message as aoperational guide to helps you understand how to
use meter.
Setup menu lets user customize calibration points, ion concentration
units, stability conditions, temperature units, date and time to meet
measurement requirements.
Reset function can resumes all settings to factory default values.
Expanded memory stores and recalls up to 500 readings.
Built-in real-time clock stamps stored data to meets GLP standards.
Stored data can be transferred into computer... |
Ion Meters
|
|
|
|
BANTE 931-S Precision Sulphide Ion Meter
|
Features:
2 to 5 points push-button calibration from low to high concentrations.
Selectable multiple concentration units, including ppm, mg/L and mol/L.
Direct readout ion concentration simplifies the elaborate measurement
process.
mV measurement allows user to check performance of ion electrode.
AutomaticTemperature Compensation (ATC) ensures highly accurate
measurements over the entire range.
Automatic endpoint function freezes the stable measured values for
easy reading and recording data.
Calibration due reminder prompts you to calibrate the meter regularly.
Help message as aoperational guide to helps you understand how to
use meter.
Setup menu lets user customize calibration points, ion concentration
units, stability conditions, temperature units, date and time to meet
measurement requirements.
Reset function can resumes all settings to factory default values.
Expanded memory stores and recalls up to 500 readings.
Built-in real-time clock stamps stored data to meets GLP standards.
Stored data can be transferred into computer... |
Ion Meters
|
|
|
|
BANTE ORPscan10 Pocket ORP Tester
|
ORPscan10 pocket ORP tester is used to monitors chemical
reactions, quantify ion activity, or determine the oxidizing or
reducing properties of samples. The meter is widely used in
pharmaceutical research, aquaculture and food processing
industry, etc.
Features:
Absolute or Relative mV measurements provides accurate readings.
Single point offset calibration allows you adjust displayed value to a
known standard.
Hold function freezes current displayed value for easy viewing and
recording.
Auto-power off feature helps you effectively conserve battery life.
Setup menu lets user customizes automatic or manual hold function,
auto-power off feature to meet your personal preferences.
Reset feature allows user to resume all of the default settings.
Replaceable electrode reduces maintenance and replacement costs.
Waterproof feature to ensures complete protection in harsh
environments.
|
Oxidation Reduction Potential Meters
|
|
|
|
BANTE ORPscan20 Pocket ORP Tester
|
ORPscan20 pocket ORP tester is used to monitors chemical
reactions, quantify ion activity, or determine the oxidizing or
reducing properties of samples. The meter has a BNC plug
which can connect any standard ORP electrode.
Features:
Absolute or Relative mV measurements provides accurate readings.
Single point offset calibration allows you adjust displayed value to a
known standard.
Hold function freezes current displayed value for easy viewing and
recording.
Auto-power off feature helps you effectively conserve battery life.
Setup menu lets user customizes automatic or manual hold function,
auto-power off feature to meet your personal preferences.
Reset feature allows user to resume all of the default settings.
Replaceable electrode reduces maintenance and replacement costs.
Waterproof feature to ensures complete protection in harsh
environments.
|
Oxidation Reduction Potential Meters
|
|
|
|
BANTE 220 Portable pH/mV/°C/°F Meter
|
Bante220 is an economical portable pH/mV meter designed for
outdoor applications, which is equipped with a large LCD and
a standard BNC connecter. The meter is capable of connecting
the various pH electrodes to measure the pH value of samples.
Features:
2 points push-button calibration with auto-buffer recognition.
Automatically calculates and shows electrode slope after calibration.
Selectable temperature unit between degrees Celsiusanddegrees
Fahrenheit.
Automatic Temperature Compensationensures highly accurate
measurement over the entire pH range.
Hold function freezes the current displayed value for easy viewing.
Help message as a operational guide that can help you quickly use
the meter.
Setup menu allows user to customize temperature unit, date and time
for measurement requirements.
Expanded memory stores and recalls up to 50 readings.
Built-in real-time clock stamps stored data to meet GLP standards.
Stored data can be transferred into computer via USB communication
interface.
|