Fluke 700-BCA Bar Code Adapter
|
Shielded four conductor cable terminated with a 9-socket D-subminiature connector and a 9-pin D-subminiature connector.
Provides interconnection and pin translation between a Fluke 743 Documenting Process Calibrator and a Hewlett Packard HBSW-8200 Bar Code Wand.
Overall length approximately 15 cm
One year warranty
|
Connectors
|
|
|
|
Fluke 700-IV Current Shunt
|
Very accurate current shunt to use for verification and calibration of process control loops.
Can be used with accurate voltmeters for calibration purposes
Can be used with Fluke 74X series in mA/mA applications (74X will display mA/mA automatically) One year warranty
|
Connectors
|
|
|
|
Fluke TPS FLEX 36-TF 3000A/6000A Thin Flex Flexible Current Probe with 36-inch Cable For the Fluke 1760 Power Recorder
|
Measuring Range selectable per software:
30A to 3000A
60A to 6000A
Peak current for sinusoidal currents:
10kA
19kA
Intrinsic error 1%
Frequency Range 45 Hz to 3.0 kHz
Operating Voltage 300 V CAT IV
Phase Error 0.5°
Jaw Opening 45 cm length 2 m cable
|
Current Clamps
|
|
|
|
Fluke TPS FLEX 24-TF 200A/1000A Thin Flex Flexible Current Probe with 24-inch Cable For the Fluke 1760 Power Recorder
|
Measuring Range selectable per software:
2A to 200A
10A to 1000A
Peak current for sinusoidal currents:
480A
2700A
Intrinsic error 1%
Frequency Range 45 Hz to 3.0 kHz
Operating Voltage 600 V CAT IV
Phase Error 0.5°
Jaw Opening 45 cm length 2 m cable
|
Current Clamps
|
|
|
|
Fluke TPS FLEX 18-TF 100A/500A Thin Flex Flexible Current Probe with 18-inch Cable For the Fluke 1760 Power Recorder
|
Measuring Range selectable per software:
1A to 100A
5A to 500A
Peak current for sinusoidal currents:
240A
1350A
Intrinsic error 1%
Frequency Range 45 Hz to 3.0 kHz
Operating Voltage 300 V CAT IV
Phase Error 0.5°
Jaw Opening 45 cm length 2 m cable
|
Current Clamps
|
|
|
|
Fluke TPS CLAMP 50 A / 5 A Clip-on Current Transformer
|
Measuring Range selectable per software 1 A to 100 A 5 A to 500 A
Peak current for sinusoidal currents 240 A 1350 A
Intrinsic error 1%
Frequency Range 45 Hz to 3.0 kHz
Operating Voltage 300 V CAT IV
Phase Error 0.5 °
Jaw Opening 45 cm length
2 m cable
Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz
Phase angle error at nominal current
Imax maximum current without time limit (for ac and dc shunts)
|
Current Clamps
|
|
|
|
Fluke TPS CLAMP 200 A / 20 A Clip-on Current Transformer
|
Measuring Range selectable per software:0.2 A to 20 A 2 A to 200 A
Peak current for sinusoidal currents74 A 300 A
Intrinsic error 0.5%
Frequency Range 40 Hz to 10 kHz
Operating Voltage 300 V CAT IV
Phase Error 0.5 °
Jaw Opening < 15 mm diameter or 15 x 17 mm bus bars
Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz
Phase angle error at nominal current
Imax maximum current without time limit (for ac and dc shunts)
|
Current Clamps
|
|
|
|
Fluke TPS CLAMP 10 A / 1 A Clip-on Current Transformer
|
Measuring Range selectable per software:0.01A to 1A0.1A to 10A
Peak current for sinusoidal currents:3.7A to 37A
Intrinsic error: 0.5%
Frequency Range: 40Hz to 10kHz
Operating Voltage: 300V CAT IV
Phase Error: 0.5°
Jaw Opening: <15mm diameter or 15x17mm bus bars
Errors in % of measuring range at 23°C ± 2K; 74°F±2K, for 48 to 65Hz
Phase angle error at nominal current
Imax maximum current without time limit (for ac and dc shunts)
|
Current Clamps
|
|